amplatzer plug Search Results


90
AGA Medical corp amplatz vascular plugs
Amplatz Vascular Plugs, supplied by AGA Medical corp, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/amplatzer+plug/pmc03444873-132-9-12?v=AGA+Medical+corp
Average 90 stars, based on 1 article reviews
amplatz vascular plugs - by Bioz Stars, 2026-07
90/100 stars
  Buy from Supplier

90
AGA Medical corp amplatzertm cardiac plug
Amplatzertm Cardiac Plug, supplied by AGA Medical corp, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/amplatzer+plug/10__1161_slash_circoutcomes__115__002539-404-10-17?v=AGA+Medical+corp
Average 90 stars, based on 1 article reviews
amplatzertm cardiac plug - by Bioz Stars, 2026-07
90/100 stars
  Buy from Supplier

90
AGA Medical corp amplatzer avp plug 1.2 or 4
Amplatzer Avp Plug 1.2 Or 4, supplied by AGA Medical corp, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/amplatzer+plug/pm22240331-79-1-3?v=AGA+Medical+corp
Average 90 stars, based on 1 article reviews
amplatzer avp plug 1.2 or 4 - by Bioz Stars, 2026-07
90/100 stars
  Buy from Supplier

90
Medtronic inc amplatzer plug
Amplatzer Plug, supplied by Medtronic inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/amplatzer+plug/pm34781751-67-20-22?v=Medtronic+inc
Average 90 stars, based on 1 article reviews
amplatzer plug - by Bioz Stars, 2026-07
90/100 stars
  Buy from Supplier

90
Occlutech GmbH amplatzer vascular plug iii
Amplatzer Vascular Plug Iii, supplied by Occlutech GmbH, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/amplatzer+plug/pm36614920-217-12-22?v=Occlutech+GmbH
Average 90 stars, based on 1 article reviews
amplatzer vascular plug iii - by Bioz Stars, 2026-07
90/100 stars
  Buy from Supplier

90
AGA Medical corp 10-mm amplatzer plug
10 Mm Amplatzer Plug, supplied by AGA Medical corp, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/amplatzer+plug/pm21784607-50-20-22?v=AGA+Medical+corp
Average 90 stars, based on 1 article reviews
10-mm amplatzer plug - by Bioz Stars, 2026-07
90/100 stars
  Buy from Supplier

90
AGA Medical corp an 8-mm-diameter × 7-mm-long nitinol-based amplatzer vascular plug
An 8 Mm Diameter × 7 Mm Long Nitinol Based Amplatzer Vascular Plug, supplied by AGA Medical corp, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/amplatzer+plug/pmc08590276-21-16-20?v=AGA+Medical+corp
Average 90 stars, based on 1 article reviews
an 8-mm-diameter × 7-mm-long nitinol-based amplatzer vascular plug - by Bioz Stars, 2026-07
90/100 stars
  Buy from Supplier

90
AGA Medical corp plug 10mm amplatzer vascular plug
Angiography findings. ( A <t>)</t> <t>Embolization</t> of right common iliac artery was performed with <t>PLUG</t> 10 mm (dotted arrow). ( B ) Pelvic arteriogram showed aneurysmal dilatation of right common iliac artery, iliocaval shunt and some filling defects near the aneurysm (white arrow indicate thrombus). ( C ) Angiography after deployment of the stents showed well implanted graft stents and no visible of IVC.
Plug 10mm Amplatzer Vascular Plug, supplied by AGA Medical corp, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/amplatzer+plug/pmc03924014-37-12-17?v=AGA+Medical+corp
Average 90 stars, based on 1 article reviews
plug 10mm amplatzer vascular plug - by Bioz Stars, 2026-07
90/100 stars
  Buy from Supplier

86
Abbott Laboratories amplatzer pfo occluder
Angiography findings. ( A <t>)</t> <t>Embolization</t> of right common iliac artery was performed with <t>PLUG</t> 10 mm (dotted arrow). ( B ) Pelvic arteriogram showed aneurysmal dilatation of right common iliac artery, iliocaval shunt and some filling defects near the aneurysm (white arrow indicate thrombus). ( C ) Angiography after deployment of the stents showed well implanted graft stents and no visible of IVC.
Amplatzer Pfo Occluder, supplied by Abbott Laboratories, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/amplatzer+plug/pmc12454762-48-7-16?v=Abbott+Laboratories
Average 86 stars, based on 1 article reviews
amplatzer pfo occluder - by Bioz Stars, 2026-07
86/100 stars
  Buy from Supplier

86
Lifetech Scientific Corporation device
Angiography findings. ( A <t>)</t> <t>Embolization</t> of right common iliac artery was performed with <t>PLUG</t> 10 mm (dotted arrow). ( B ) Pelvic arteriogram showed aneurysmal dilatation of right common iliac artery, iliocaval shunt and some filling defects near the aneurysm (white arrow indicate thrombus). ( C ) Angiography after deployment of the stents showed well implanted graft stents and no visible of IVC.
Device, supplied by Lifetech Scientific Corporation, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/amplatzer+plug/pm41563226-102-65-74?v=Lifetech+Scientific+Corporation
Average 86 stars, based on 1 article reviews
device - by Bioz Stars, 2026-07
86/100 stars
  Buy from Supplier

86
Johnson & Johnson amplatzer duct occluder ii 5 4
A , Baseline aortic angiogram in RAO showing a 3‐mm type A PDA; B , Aortic angiogram in the same projection following deployment of an MFO 6–4 (no PTFE membrane) showing a well‐positioned device with mild residual intraprosthetic shunt; C , Baseline aortic angiogram in the lateral projection; D , Aortic angiogram (lateral projection) following device deployment confirming a well‐positioned device. MFO indicates multifunctional <t>occluder;</t> PDA, patent ductus arteriosus; and RAO, right anterior oblique.
Amplatzer Duct Occluder Ii 5 4, supplied by Johnson & Johnson, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/amplatzer+plug/pmc12684515-166-21-26?v=Johnson+%26+Johnson
Average 86 stars, based on 1 article reviews
amplatzer duct occluder ii 5 4 - by Bioz Stars, 2026-07
86/100 stars
  Buy from Supplier

86
St Jude Medical amplatzer vascular plug
Procedure for making the physician-modified vascular plug (PMVP) and intraoperative angiogram of the PMVP placement technique. A , An expanded polytetrafluoroethylene (ePTFE) prosthetic patch shaped and drilled in the center of the patch and an <t>Amplatzer</t> Vascular Plug. B, Completed PMVP. C, After 2 disks were deployed on the false lumen by unsheathing, the third was deployed in the true lumen. Successful occlusion was confirmed by the angiogram before deployment.
Amplatzer Vascular Plug, supplied by St Jude Medical, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/amplatzer+plug/pmc12813561-80-8-13?v=St+Jude+Medical
Average 86 stars, based on 1 article reviews
amplatzer vascular plug - by Bioz Stars, 2026-07
86/100 stars
  Buy from Supplier

Image Search Results


Angiography findings. ( A ) Embolization of right common iliac artery was performed with PLUG 10 mm (dotted arrow). ( B ) Pelvic arteriogram showed aneurysmal dilatation of right common iliac artery, iliocaval shunt and some filling defects near the aneurysm (white arrow indicate thrombus). ( C ) Angiography after deployment of the stents showed well implanted graft stents and no visible of IVC.

Journal: Journal of Korean Medical Science

Article Title: Iliocaval Fistula Presenting with Paradoxical Pulmonary Embolism Combined with High-Output Heart Failure Successfully Treated by Endovascular Stent-Graft Repair: Case Report

doi: 10.3346/jkms.2014.29.2.296

Figure Lengend Snippet: Angiography findings. ( A ) Embolization of right common iliac artery was performed with PLUG 10 mm (dotted arrow). ( B ) Pelvic arteriogram showed aneurysmal dilatation of right common iliac artery, iliocaval shunt and some filling defects near the aneurysm (white arrow indicate thrombus). ( C ) Angiography after deployment of the stents showed well implanted graft stents and no visible of IVC.

Article Snippet: For a start embolization of right common iliac artery was performed with PLUG 10mm (Amplatzer vascluar plug, Aga Medical Corp) ( ).

Techniques:

A , Baseline aortic angiogram in RAO showing a 3‐mm type A PDA; B , Aortic angiogram in the same projection following deployment of an MFO 6–4 (no PTFE membrane) showing a well‐positioned device with mild residual intraprosthetic shunt; C , Baseline aortic angiogram in the lateral projection; D , Aortic angiogram (lateral projection) following device deployment confirming a well‐positioned device. MFO indicates multifunctional occluder; PDA, patent ductus arteriosus; and RAO, right anterior oblique.

Journal: Journal of the American Heart Association: Cardiovascular and Cerebrovascular Disease

Article Title: Off‐Label Use of the Multifunctional Occluder for Transcatheter Patent Ductus Arteriosus Closure: An International Experience

doi: 10.1161/JAHA.125.043468

Figure Lengend Snippet: A , Baseline aortic angiogram in RAO showing a 3‐mm type A PDA; B , Aortic angiogram in the same projection following deployment of an MFO 6–4 (no PTFE membrane) showing a well‐positioned device with mild residual intraprosthetic shunt; C , Baseline aortic angiogram in the lateral projection; D , Aortic angiogram (lateral projection) following device deployment confirming a well‐positioned device. MFO indicates multifunctional occluder; PDA, patent ductus arteriosus; and RAO, right anterior oblique.

Article Snippet: The intraprocedural TTE showed device protrusion causing mild acquired aortic obstruction, leading to device retrieval and successful PDA closure with an Amplatzer Duct Occluder II 5/4 (Abbott Medical, Plymouth, MN, USA) during the same case.

Techniques: Membrane

A , Laminar color flow in descending aorta; B , Color wave Doppler velocity demonstrated no obstruction in the aorta with a peak velocity of 1.5 m/s; C , The MFO device was seen with no residual shunt at postprocedural Day 1, with laminar flow into LPA; D , Color wave Doppler velocity demonstrated no obstruction in the LPA with a peak velocity of 1.5 m/s. LPA indicates left pulmonary artery; MFO, multifunctional occluder; and RPA, right pulmonary artery.

Journal: Journal of the American Heart Association: Cardiovascular and Cerebrovascular Disease

Article Title: Off‐Label Use of the Multifunctional Occluder for Transcatheter Patent Ductus Arteriosus Closure: An International Experience

doi: 10.1161/JAHA.125.043468

Figure Lengend Snippet: A , Laminar color flow in descending aorta; B , Color wave Doppler velocity demonstrated no obstruction in the aorta with a peak velocity of 1.5 m/s; C , The MFO device was seen with no residual shunt at postprocedural Day 1, with laminar flow into LPA; D , Color wave Doppler velocity demonstrated no obstruction in the LPA with a peak velocity of 1.5 m/s. LPA indicates left pulmonary artery; MFO, multifunctional occluder; and RPA, right pulmonary artery.

Article Snippet: The intraprocedural TTE showed device protrusion causing mild acquired aortic obstruction, leading to device retrieval and successful PDA closure with an Amplatzer Duct Occluder II 5/4 (Abbott Medical, Plymouth, MN, USA) during the same case.

Techniques:

A , Baseline lateral aortic angiogram demonstrating a 7.6 mm, Type A PDA; B , Lateral aortic angiogram following deployment of an MFO 14–12 (PTFE membrane) showing a well‐positioned device with immediate shunt occlusion. MFO indicates multifunctional occluder; and PDA, patent ductus arteriosus.

Journal: Journal of the American Heart Association: Cardiovascular and Cerebrovascular Disease

Article Title: Off‐Label Use of the Multifunctional Occluder for Transcatheter Patent Ductus Arteriosus Closure: An International Experience

doi: 10.1161/JAHA.125.043468

Figure Lengend Snippet: A , Baseline lateral aortic angiogram demonstrating a 7.6 mm, Type A PDA; B , Lateral aortic angiogram following deployment of an MFO 14–12 (PTFE membrane) showing a well‐positioned device with immediate shunt occlusion. MFO indicates multifunctional occluder; and PDA, patent ductus arteriosus.

Article Snippet: The intraprocedural TTE showed device protrusion causing mild acquired aortic obstruction, leading to device retrieval and successful PDA closure with an Amplatzer Duct Occluder II 5/4 (Abbott Medical, Plymouth, MN, USA) during the same case.

Techniques: Membrane

A , Initial aortic angiogram in the lateral projection demonstrated a short, type B PDA (4.5 mm minimal diameter, 4 mm length); B , Aortic angiogram after release of an MFO 8–6 (no PTFE membrane) showing mild intraprosthetic shunt; C , The aortic angiogram in the lateral projection at the time of reintervention showing significant intraprosthetic residual shunt; D , The final aortic angiogram in the lateral projection following transcatheter retrieval of the MFO 8–6 and implantation of an MFO 9–5 (PTFE membrane) demonstrating a well‐positioned device with immediate shunt occlusion. The aortic disc is well conformed with a descending aortic peak velocity of 1.6 m/s at discharge. MFO indicates multifunctional occluder; and PDA, patent ductus arteriosus.

Journal: Journal of the American Heart Association: Cardiovascular and Cerebrovascular Disease

Article Title: Off‐Label Use of the Multifunctional Occluder for Transcatheter Patent Ductus Arteriosus Closure: An International Experience

doi: 10.1161/JAHA.125.043468

Figure Lengend Snippet: A , Initial aortic angiogram in the lateral projection demonstrated a short, type B PDA (4.5 mm minimal diameter, 4 mm length); B , Aortic angiogram after release of an MFO 8–6 (no PTFE membrane) showing mild intraprosthetic shunt; C , The aortic angiogram in the lateral projection at the time of reintervention showing significant intraprosthetic residual shunt; D , The final aortic angiogram in the lateral projection following transcatheter retrieval of the MFO 8–6 and implantation of an MFO 9–5 (PTFE membrane) demonstrating a well‐positioned device with immediate shunt occlusion. The aortic disc is well conformed with a descending aortic peak velocity of 1.6 m/s at discharge. MFO indicates multifunctional occluder; and PDA, patent ductus arteriosus.

Article Snippet: The intraprocedural TTE showed device protrusion causing mild acquired aortic obstruction, leading to device retrieval and successful PDA closure with an Amplatzer Duct Occluder II 5/4 (Abbott Medical, Plymouth, MN, USA) during the same case.

Techniques: Membrane

Procedure for making the physician-modified vascular plug (PMVP) and intraoperative angiogram of the PMVP placement technique. A , An expanded polytetrafluoroethylene (ePTFE) prosthetic patch shaped and drilled in the center of the patch and an Amplatzer Vascular Plug. B, Completed PMVP. C, After 2 disks were deployed on the false lumen by unsheathing, the third was deployed in the true lumen. Successful occlusion was confirmed by the angiogram before deployment.

Journal: Journal of Vascular Surgery Cases, Innovations and Techniques

Article Title: Physician-modified vascular plug for entry closure of a chronic aneurysmal aortic dissection

doi: 10.1016/j.jvscit.2025.102100

Figure Lengend Snippet: Procedure for making the physician-modified vascular plug (PMVP) and intraoperative angiogram of the PMVP placement technique. A , An expanded polytetrafluoroethylene (ePTFE) prosthetic patch shaped and drilled in the center of the patch and an Amplatzer Vascular Plug. B, Completed PMVP. C, After 2 disks were deployed on the false lumen by unsheathing, the third was deployed in the true lumen. Successful occlusion was confirmed by the angiogram before deployment.

Article Snippet: To make the PMVP, we used an 8-mm Amplatzer Vascular Plug (AVP II; St Jude Medical), which was approximately 2 mm larger than the diameter of the intimal defect, and an expanded polytetrafluoroethylene (ePTFE) prosthetic patch (Gore Preclude Pericardial Membrane; W. L. Gore).

Techniques: Modification

Occlusion image using a physician-modified vascular plug (PMVP). AVP II , Amplatzer Vascular Plug II; ePTFE , expanded polytetrafluoroethylene.

Journal: Journal of Vascular Surgery Cases, Innovations and Techniques

Article Title: Physician-modified vascular plug for entry closure of a chronic aneurysmal aortic dissection

doi: 10.1016/j.jvscit.2025.102100

Figure Lengend Snippet: Occlusion image using a physician-modified vascular plug (PMVP). AVP II , Amplatzer Vascular Plug II; ePTFE , expanded polytetrafluoroethylene.

Article Snippet: To make the PMVP, we used an 8-mm Amplatzer Vascular Plug (AVP II; St Jude Medical), which was approximately 2 mm larger than the diameter of the intimal defect, and an expanded polytetrafluoroethylene (ePTFE) prosthetic patch (Gore Preclude Pericardial Membrane; W. L. Gore).